YARDY EV3

Cooling capacity: 1.1÷8.5 kW
Heating capacity: 1.6÷11.7 kW

Plus Product

  •  Enhanced performance with 4 row coil
  •  Acoustic comfort
  •  6 speed fan
  •  Installation flexibility
  • Pre-fitted accessories and controls
YARDY EV3 gruppo.600x415.best_fit

Floor, or ceiling, recessed wall or false ceiling installation fan coils with cabinet.

Construction features

• Heat exchanger: finned coil with left-hand connections reversible to right.

• 6-speed centrifugal fan, of which 3 speeds are connected to the terminal board.

• Cover cabinet version structure: covering cabinet in pre-painted sheet metal complete with renewable filter, ABS polymer grilles and condensation drain pan with natural drainage.

• Recessed version structure: in galvanised sheet steel, complete with condensation drain pan with natural drainage and renewable filter.

Versions

• MVP – Vertical unit with cabinet equipped with lower air inlet and upper outlet for wall mounting or with feet on ground.

• MVT – Vertical unit with cabinet equipped with front air inlet and upper outlet for floor installation.

• MXP – Horizontal/vertical unit with cabinet, equipped with lower air inlet and upper outlet, for ceiling installation, wall-mounting or with feet on ground.

• MXT – Vertical unit with cabinet equipped with front air inlet and upper outlet for floor installation.

• IVP – Vertical unit with cabinet equipped with front air inlet and upper outlet for floor installation.

• IVF – Recessed vertical unit equipped with lower air inlet and front outlet for wall installation.

• IXP – Horizontal/vertical unit equipped with lower air inlet and upper outlet for false ceiling or recessed wall installation.

Accessories

➔❖Additional water heating coil.

➔❖Electrical heater.

➔❖ON/OFF 2-way valves for 2 and 4-pipe-systems.

➔❖ON/OFF 3-way valves for 2 and 4-pipe-systems.

➔❖Auxiliary condensation drain pan.

➔ Manual damper.

➔ Motorised damper.

➔ Rear panel.

➔ Rear closure panel.

➔ Rear closure panel with grille and filter.

➔ Support feet with pipe cover.

STANDARD Controls

For wall mounting installation

➔ Panel with speed and summer/winter switch.

➔ Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electrical heater.

➔ Minimum temperature thermostat (for installation on the machine).

➔ Electronic panel with automatic summer/winter changeover for 2-pipe systems.

➔ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe systems with electrical resistance or 4-pipe systems.

➔ Electronic panel with display and RS485 serial interface, semi-recessed in wall.

For installation on machine (MVP and MVT versions)

➔❖Panel with speed and summer/winter switch.

➔❖Panel with room thermostat, summer/winter switch and speed switch.

➔❖Minimum temperature thermostat.

➔❖Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electrical heater.

➔❖Electronic panel with automatic summer/winter changeover for 2-pipe systems.

➔❖Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe systems with electrical resistance or 4-pipe systems.

➔ Interface board for controlling up to 4 fan coils.

AIRWAVE CONTROLS

➔ Wall mounting receiver with remote control.

➔ Electronic panel for wall or on board mounting.

➔ Wall-mounted recessed electronic panel.

For installation on machine

➔❖Master/slave electronic board.

➔❖Temperature probe for hot row.

➔❖Module for ON/OFF valves and electrical heater management.

➔ RS485 interface for serial communication with other devices (proprietary protocol; Modbus RTU protocol).

➔ RS485/USB serial converter.

➔ Serial interface (CAN-bus – Controller Area Network) for the airwave system.

➔ KGTW-BAC- Gateway RS485/BACnet (max 64 fan coil).

➔ KGW-LON- Gateway RS485/FTT10-LonWorks (max 64 fan coil).

Key: ❖ Factory fitted

➔ Supplied loose

Data at the following conditions:
Air: 27°C D.B.; 19°C W.B. – Acqua: 7/12°C.
Air: 20°C – Water: 45/40°C.
Air: 20°C – Water: 50°C, flow rate as in cooling.
Air: 20°C – Water: 70/60°C.
Air: 20°C – Water: 65/55°C.
For room volume equal to 100 m³ and reverberation time = 0.5 sec.
Wired speed in terminal block.
E Eurovent certificated performance.
Yardy EV3 24 – 34 – 48 – 74 – 88 with oversized 4-row coil.